M302 p1. Thermostatic control is turned on > 45C turn on ;M106 P1 S255 H-1 M302 P1 ; Allow cold extrusion (for testing) T0 ; Set tool 0 (default extruder) G21 ; Work in millimetres G90 ; Send absolute coordinates. M302 p1

 
Thermostatic control is turned on > 45C turn on ;M106 P1 S255 H-1 M302 P1 ; Allow cold extrusion (for testing) T0 ; Set tool 0 (default extruder) G21 ; Work in millimetres G90 ; Send absolute coordinatesM302 p1

This topic has been deleted. Chances are you are getting a message saying either "Attempt to extrude with no tool selected" or "Tool n was not driven because its heaters were not hot enough". To test for this, with the power off swap the E0 connector on the Duet with another one e. @agent0810 said in Homing advice: i was able to. If that's not the case, we need to change the direction of rotation. 4. Re: Extrude without a Hotend May 04, 2017 11:25PM. Last edit at 01/11/2023 01:58AM by Dust. So no need to use M302. I've now managed to calibrate my Steps/mm of the extruder by manually issuing G1 commands. g. 1 Reply Last reply Reply Quote 0. M570 S180 ; allow it 180 seconds before gving a heating warning and test hotends wont be tuned. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. Re: Extrude without a Hotend. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. Chances are you are getting a message saying either "Attempt to extrude with no tool selected" or "Tool n was not driven because its heaters were not hot enough". The macro folder can divided into sub directories to more easily organise your macros by type. Why happening freezes while running this g-code? G28 ; Homing T0 ; Select tool T0 M83 ; Extruder to relative mode M302 P1 ; Allow cold extrudes G1 X20 F9000 G1 X80 E1 F9000 ;freeze G1 X120 F9000 G1 X80 E1 F9000 ;freeze G1 X20 F9. retraction temperature 90. it has a bowden setup and i have the bowden tube off. How bout if you heat up the hotend to 180?How bout if you heat up the hotend to 180?How bout if you heat up the hotend to 180?M302 P1 ; Allow cold extrusion Just enter the above code from your host software (pronterface or repitear) and you should be good to test the paste extruder. 2 the M302 P1 command doesn't help to allow the cold extrusion anymore. Business, Economics, and Finance. Actual. I just wondered if there was a way of "embedding" it in the config files so that it runs by default. When I print using the code below (it is longer, but I do not know where to put attachments), I can see that the extruder-gear is jerking, as if it tries to do tiny retractions between every little movement. G1 E500 F300. If you want to test your extruder, you can disable cold extrusion prevention using M302: M302 P1. com ], E3D tool changer, Robotdigg SCARA printer, Crane. Zuletzt am 03. ; pre 3. 1 Reply Last reply Reply Quote 0 M302 ; report current cold extrusion state M302 P0 ; enable cold extrusion checking M302 P1 ; disable cold extrusion checking M302 S0 ; always allow extrusion (disable checking) M302 S170 ; only allow extrusion above 170 M302 S170 P1 ; set min extrude temp to 170 but leave disabled I've processed a lot of the same flights in Terra, Pix4D, and Agisoft. This topic has been deleted. g. Other possible causes are a bad stepper motor or cable. Reply Quote. To test for this, with the power off swap the E0 connector on the Duet with another one e. . @dsela. Hello, I am building a clay printer and everything is working fine so far (with your help). Send T0 in the gcode console and check the buttons again. To test for this, with the power off swap the E0 connector on the Duet with another one e. Re-enable with. Features solid metallic core with. e. Large delta printer [ miscsolutions. Part Type: Rear Main Seals. Currently the paneldue displays the thermistor readings appropriately for thermistor 1 and 2 of the Duex5, which leads me to believe that the Duex5 is wired correctly. . . Once satisfied the extruder drive is working, re-enable cold extrusion prevention using the following command: M302 P0 Reset the Active temperature for Heater 1 back to 190C. G1 E200 F500 ; extrude 200mm, you may need to reduce speed for very soft TPU. 3. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. wordpress. 4. Other possible causes are a bad stepper motor or cable. 0. Send M302 P1 to allow Cold extrusion; Send M600 T1 to initiate Filament swap; Follow the Instructions on the Screen. 0. ) You can feed filament at 800mm/m (web interface max speed is 240mm/m), at 100mm at a time, until the filament is near the nozzle. I can't move the cold extruder to load the wire. With steps/mm so low you will get nothing like enough torque out of your motor to extrude anything, unless it is a really huge motor. extrusion temperature 160. 4. M302 P1 M563 P0 D0 T1 ;enable cold extrusion. M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. Support and Discussion forum for Duet3D Hardware, Firmware, Software, plugins and wider 3d printing/CNC discussion. Heater 1 fault: temperature rising too slowly: expected 2. I would be very gratefull for any help. and Terra makes the best looking meshes by far. 3rd print: Layer shift of 3mm at layer 3 starting somewhere at 30x25. Extrude a small amount to ensure that your extruder motor is on and holding. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. Heater 1 fault: temperature rising too slowly: expected 2. 0 S1 ; physical drive 1. My config file is in experimental stages, but the Cartesian axis worked. wordpress. Orange - unload button is pressed (only when filament is present) Please note the filament sensing button used here is not a standard TACT switch. @droftarts OK, I wish I knew which of the changes finally mattered but I don't. Viko. . Good morning. : till no luck with Extrusion Control jogging buttons. 0C, min. 5 (2022-11-30 19:41:16) running on Duet 3 Mini5plus WiFi (SBC mode)M302 P1 ; cold extrude: G92 × 0 Y0 Z0 ; set current position to {X = 0,Y = 0,Z = 0} G92 E0 ;zero the extruded length: G1 F200 E0. 0. g. I used M302 P1 and it worked fine when I was testing my new extruder stepper motor. Featured product areas:As well as selecting the tool with e. 36°C/sec measured -0. P1: Acute abdominal pain (e. one immediately before X). (You will have to switch off the temperature control as most controllers will not move the extruder stepper unless the hot end it up to temperature) Use M302 P1 on RepRapFirmware to switch cold extrusion on (allow extrusion while cold) and M302 P0 to switch it off again. G1 F200 E0. Volume 2. retraction temperature 90. Wood filament wont extrude / print below 200deg. microswitch) endstop. Repetier 1. 1 Reply Last reply Reply Quote 0. CryptoM21 P1 M22 Release SD card M23 [filename. I use duet wifi version 1. 455513e-8My printer has sat for a couple of months because well, moving. Surely there must be a way to do cold extrusion (no heater, no thermistor) for those of us who don't want to extrude hot filament?M302 P1; Allow cold extrude : T0; select tool 0: G10 P0 S180; heat tool 0 to 180 and wait: M116 P0: G10 P0 S120; cool tool 0 to 120 and wait: M116 P0: G1 E-20 F300; retract 20mm at 5mm/sec; change the following E values to suit your Bowden Tube length : G1 E-50 F600; retract another 50mm at 10mm/sec: G1 E-200 F3000; retract another 150mm at. com], E3D tool changer, Robotdigg SCARA printer, Crane Quad and OrmerodDisclosure: I design Duet electronics and work on RepRapFirmware, []. 3 ; Filter. 1 Reply Last reply Reply Quote 0. Reply Quote. retraction temperature 90. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. Duet 3 mini 5+ installed in a Sidewinder x1 v1. Re-enable with. 8 is far too low for two reasons: 1. 36°C/sec measured -0. Reply Quote. Crypto3D Printer Chess. Ofc this is all thanks to Duet3D advanced pause that has. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. Anytime I extrude a certain length of filament, the extruder retracts the same length it seems. Large delta printer [miscsolutions. Surely there must be a way to do cold extrusion (no heater, no thermistor) for those of us who don't want to extrude hot filament?12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. Macros also allow for naming gcodes with easier to remember names. 1. 1 Reply Last reply Reply Quote 0. 2. Example output if disabled: echo:Cold extrudes are disabled (min temp 170C) Example output if enabled: To temporarily disable the MIN_TEMP, you need to run the G-code M302 P1 or M302 S0 - M302 on its own does nothing. 00°C/sec When you try to heat does the LED near the heater terminal actually turn on? Can. When setting my Anet A8 printer at that temp, the extruder motor doesn't turn by… Beat me to it! If the current tool doesn't have any heaters assigned to it, extrusion is allowed always. 0. : Just need to find settings for Slice Engineering 300c thermistor, According to this document, you need to use the following in your M308 T100000 B4680 C6. G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Hello. retraction temperature 90. These are commands that one may enter into the OctoPrint terminal tab. 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. wordpress. g. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. It's simple. Command "M302 P1" works properly. This value gives better accuracy at typical printing temperatures in the range 190 to 250C than the B value of 4267 quoted in the datasheet. 1 Reply Last reply Reply Quote 0. I would be very gratefull for any help. Trying to figure out why I can't run my extruder. M302 P0 S170. Click to Enlarge. G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Green - filament present. If calibrating cold: Bowden: Disconnect the bowden tube from your extruder. Direct drive: Remove your nozzle, hotend, or extruder. M106 P1 S1 H1 T100 ; set fan 1 value. droftarts administrators @flyscha last edited by . g. M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. The extruder can't always move as fast s the other axes, that's why my examples to move E use a slower speed (F value). Still no luck with Extrusion Control jogging buttons. 100". Compatible with the FlightHub 2 cloud platform and DJI Dock to achieve cloud collaboration and. Reply Quote. 3 ; Filter. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. Even I set M302 P1, the extruder control panel can't be use. As well as selecting the tool with e. What could be the causeMarlin defaults to "no cold extrusion". This document describes the commands that Klipper supports. Hello. Thanks. 1 Reply Last reply Reply Quote 0. M302 P1 disables the cold extrude safety. Re: How can I move E steppers? January 11, 2023 02:36AMI used the safety scissors to cut off the fingers of the severed hand then tried to give her the fingers. 0C. Now with Marilin 2. I have been clicking the 'retract' and 'extrude' button multiple times to push the plunger down to the correct position and to retract the plunger from the bottom of the cylinder after the print. 5mm/sec echo "Done" M82 ; set extruder to abs mode 1 Reply Last reply Reply Quote 0There is one extra complication in moving the extruder. @jfavre Are you sure you have a tool selected (with T0, you will need that as well as the M302 P1)? What response did you get to M302 (before and after you set M302 P1)? Have you tried heating the nozzle? 1 Reply Last reply Reply Quote 0. My pause button in webcontrol stopped working - it's ghosted with a stop-sign courser when I hover it. g. Hi all, It turned out to be the end-stops micro switches causing the board to lose connection. M302 P1; Axis Limits M208 X-50 Y0 Z0 U0 S1 ; set axis minima M208 X210 Y220 U260 Z200 S0 ; set axis maxima ; Endstops M574 X1 S1 P"io0" ; configure switch-type (e. X moves almost free, lets say as much as you can tell with the belt installed without the steppers. The belts are not over tight. 16 07:24. : M302 Just got the extruder motor to work with G1 E1 F100 andG1 E-1 F100. 4 S240 M307If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. If you want to test your extruder, you can disable cold extrusion prevention using M302: M302 P1. If calibrating cold: Bowden: Disconnect the bowden tube from your extruder. To test for this, with the power off swap the E0 connector on the Duet with another one e. 3 Then I think you should config the BLTouch differently: Have you read this bit, "Software setup (. It has a different internal construction. 3 ; Filter. x) G92 A-1 B-1 ; Make Zrot & Tilt active G1 A0 B0 ; 3. 06. For example you can create a Macro for "Allow Cold Extrude" to call M302 P1. Direct drive: Remove your nozzle, hotend, or extruder. 9Hz when using S4 or P4 Q50 resp. I used to use "Pronterface" for that. To test for this, with the power off swap the E0 connector on the Duet with another one e. Thermostatic control is turned off ; Fan for the hotend M950 F1 C"out6" L0:1000 Q50 ; create fan 1 on pin out6 and set its frequency M106 P1 S1 H1 T45 C"Hotend" ; set fan 1 value. g. M302 P1 ; disable cold extrusion checking And yes each extruder is a tool T0 G1 E20 ; move current extruder 20mm T1 G1 E20 T2 G1 E20 Edited 2 time(s). M98 Ppurge_bucket . 5. @agent0810 said in Homing advice: the z is at 0 at the top, so it cant go lower right? shouldnt it home at 300 something? im having issues moveing the bed. M302 P1 M584 E3:4;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. If you are using the web interface, go to the Gcode. Thermostatic control is turned off, Minimum fan value 0. @patel said in how to change homing sequence: corexy printer setup how to change sequence homing x,y i am using M3D promega and i need to change sequence first y axis home after x axis manual working fine by hand trigger switch x limit and y limit See h. Tried setting up the extruder on drive 4 then on drive 3. However, some firmware distributions might explicitly prevent these two commands of turning off the check. Hi there, Doesn't make a diference. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. Hooray! Again, it's just odd that everything worked with that exact same config in the previous interface. Only users with topic management privileges can see it. : M302 Just got the extruder motor to work with G1 E1 F100 andG1 E-1 F100. Note to Users This Service Manual is constructed using a system of issue letters (alphas. 0. g: 1. The 3D models contain files for a mechanical gripper that attaches to the print head of the printer and can move chess pieces around. I cannot get the extruder controls to show up in the web interface - it is greyed out. g. Zuletzt am 03. the X motor. I copied the first 2 layer g-code here, and I would like to know if anyone have an idea to solve this issue. . @deckingman Replacing the P1 with P0 in the config file was the trick! Now the retract option is available immediately when I activate the hot end heater, and when it reaches 160c, the extrude option is now available. 9mm of feed stock. I read up on the on "Connecting endstop switches - What might go wrong" and then I corrected the wiring and all is good with that. TfreeN. . How would I know to send a T0 and then M302 P1 to test the extruder? Quote dc42 Make sure you have a tool selected (e. Now I would like the printer to pause a print when the printer is running out of clay using an mechanical endstop. P1: Stroke: CT/CTA should also be considered; Appendicitis: MRI rarely indicated. 9 mm of feed stock: G92 E0 ;zero the extruded length again: G1 F900 ; set the feed-rate // Starting the print with Layer 0;Layer count: 1;LAYER:0: M107Preheat the hot end, if desired (or send M302 P1 if you intend to use the macro when the hot end is cold) Use M913 Ennn to reduce the motor current, if necessary (see #1 above) Use M83 to select relative extruder motion, in case the macro is. If you want to test your extruder, you can disable cold extrusion prevention using M302: M302 P1. I have preheated the nozzle to 160 and also tried to issue a M302 P1 but that does not help either. All models of the M1 carbine family (including the M2 and M3 carbines) fired a . M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. In order to report the current status, run. Business, Economics, and Finance. EDIT: OK, so you're using RRF 3. - Only upon M302 P1 to enable cold extrusion (if not heated) through pronterface, can I use the "Extrude" or "Reverse" button on the UI. yello3d. M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. My printer doesn't have extrusion but when I push it manually it extrudes just fine. com], E3D tool changer, Robotdigg SCARA printer, Crane Quad and OrmerodDisclosure: I design Duet electronics and work on RepRapFirmware, []. J'y connais pas grand chose dans les imprimantes 3D, moi jusque là, ça fonctionnais donc je ne m’intéressai pas trop au reste, mais là, je suis bien obligé, et donc je ne sais pas faire la commande G-code que tu m'indique, ou faire ça dans Repetier-Host ?We are using two different kinds of motors, but for the Z and E we are using we are using Nema 23 bipolar 2. I am at a loss for next step. -> no reaction at all - even after "M302 P1" What is working: Homing. Then try to extrude 5mm from Pronterface UI, there’s a button for it under the move. 26" ; configure active-high endstop for low end on Y via pin null M574 Z1 S1 P"!P1. So I attached a thermistor to the board just to "fool" the board into thinking there was an active heater but then I get temperature errors. M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. P2 S2 S2 S2 7 RTS Case earth connection. Hi I am building a machine that is not a 3D printer but as I have liked a lot Duets for years now I decided to use one as a controller in this project too. Compared with the other two materials, this conformal metasurface has the best ability to bend. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. 0. ino in the repo. After you’re done calibrating Esteps, re-enable cold extrusion temperature checking with M302 P0 As has been mentioned, heating the nozzle also works. Heaters, 24v 40W - Im using 24V 400watts power supply. Re: Help with extruder feed calibration -. 3 or later ;M17 A B G92 A0 B0 G1 A0 B0 F20000. dc42 administrators @dsela last edited by dc42 . M950 F0 C"fan0" Q500 ; create fan 0 on pin fan0 and set its frequency. Ok I will try the. 8Hz when using P4. droftarts administrators @flyscha last edited by . The home position is detected by the punch slide HP sensor (PS302). In that case, you might use M302 S65 or similar to drop the MIN_TEMP. M302 by itself displays the current cold extrusion status (RepRapFirmware). Large delta printer [miscsolutions. 1 active and standby temperatures to 0C. The commands I gave it was: T0 ; just to be sure M302 P1 ; I think it wM302 P1 ; allow cold extrusion. g. I reduced. Or send the printer code "M302 P1" (with no quotes) to allow the extruder to turn without the hotend being hot. and forward - so we have are at the point we wanted to be without. . the 0, 1,2 drivers still work fine. Agisoft less so, but still worse than Terra. 3 or later ;M17 A B G92 A0 B0 G1 A0 B0 F20000. Re: How can I move E steppers? January 11, 2023 02:36AMM302 P1 ; disable cold extrusion checking And yes each extruder is a tool T0 G1 E20 ; move current extruder 20mm T1 G1 E20 T2 G1 E20 Edited 2 time(s). When setting my Anet A8 printer at that temp, the extruder motor doesn't turn by…Beat me to it! If the current tool doesn't have any heaters assigned to it, extrusion is allowed always. Business, Economics, and Finance. Good day. I use FreeBSD 13. Thermostatic control is turned on > 45C turn on ;M106 P1 S255 H-1 M302 P1 ; Allow cold extrusion (for testing) T0 ; Set tool 0 (default extruder) G21 ; Work in millimetres G90 ; Send absolute coordinates. CryptoI did try a cold extrude M302 P1. You could also put those commands in a normal text file with the file ending ". zip. Reply Quote. The extrude and retract buttons are grayed out when the thermistors aren't connected. You could do it it by turning off the safety limit which prevents cold extrusion. 0. Pix4d often makes vertical surfaces to 45 deg where they meet the ground. M302 P1 ; enable cold extrusion G4 S1 ; wait for one second G1 E15 F500 ; load filament inside the gears M109 S235 T0 ; set hotend temperature and wait G1 E200 F500 ; extrude 200mm, you may need to reduce speed for. extrusion temperature 160. Last edit at 01/11/2023 01:58AM by Dust. The Panasoic Felios F775 conformal metasurface is shown in Figure 9c. It may have allowed the extruder to run on the 6HC but I'm thinking the DWC may have still been blocking the sending of any extrude or retraction presses while it looked only at the temperature before enabling the sowtware buttons. Does the motor turn? If yes, then probably it’s not having enough power to push the filament through the nozzle. Currently the paneldue displays the thermistor readings appropriately for thermistor 1 and 2 of the Duex5, which leads me to believe that the Duex5 is wired correctly. However,. 3, Speed 100% M106 P1 S0 I0 F4 H-1 L0. g macro is;Autoload filament macro. If that's not the case, we need to change the direction of rotation. Using Extruder-Motor by G-Code (after using M302 P1 to enable cold-extrusion) What catches my eyes is that the text "Heater1" etc. CryptoThis topic has been deleted. Business, Economics, and Finance. This topic has been deleted. I just wondered if there was a way of "embedding" it in the config files so that it runs by default. CryptoAs well as selecting the tool with e. This topic has been deleted. But if you want to extrude cold, now you know how. I would be very gratefull for any help. M302 P1 ; disable cold extrusion checking And yes each extruder is a tool T0 G1 E20 ; move current extruder 20mm T1 G1 E20 T2 G1 E20 Edited 2 time(s). droftarts administrators @flyscha last edited by . I have some fillamentum wood filament, according to the website print temperature: 170 - 185 °C, however nothing prints within this range. The labels makes it easier for me to get a feel for the group a specific command belongs to, and makes it easy to find commands related to some specific task. It was type 5 in marlin. GCode and RepRapFirmware. This will hopefully make it a bit easier for me to. Last edit at 01/11/2023 01:58AM by Dust. 0C, min. Here is a handy list of g-code commands [ reprap. Put this as first line of your custom gcode. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. M302 P1 ; enable cold extrusion M201 E1000 ; reduce extruder acceleration M915 P3 S10 F0 R0 ; set stall detection threshold M913 E100 ; set extruder motor to reduced % current M83 ; relative extrusion G1 S1 E800 F3600 ; move fast 500mm of filament M913 E100 ; set extruder motor to full current M302 P0 ; disable cold extrusion G1 E50 F300. Only users with topic management privileges can see it. I'm attempting to drive I was successful in driving a Maxon DC motor with encoder (pulled from a Stratasys Dimension 1200es BST) with a Duet 2 Wifi via a Geckodrive G320x. Here is my diagnostic file and my config. the X motor. After replacing PCB managed to get everything up and running. 2. With steps/mm so low you will get nothing like enough torque out of your motor to extrude anything, unless it is a really huge motor. gco] Select SD file M23 filename. 7. Other possible causes are a bad stepper motor or cable. 1cc. This topic has been deleted. 22. G1 E20 moves E0 as expected T1 changes tools as expected G1 E30 move E1 as expected. How would I know to send a T0 and then M302 P1 to test the extruder? Quote dc42 Make sure you have a tool selected (e. 00°C/sec. La commande G-code M302 P1 permet l'extrusion a froid. @jfavre said in Extruder motor not working. is not colored in WebControl as in the example screenshots i saw. 7 Move a motor on delta printer On delta printers, the X,Y and Z movements does not correspond to a motor movement, while for commissioning, you may want to operate each motor. is not colored in WebControl as in the example screenshots i saw. Well broadly speaking I think this is the basis for the new UM3 bed probing, the probe presses on the glass which triggers a capacitative sensor underneath. M302 works fine in a starting script or sent via console. M98 Punload . . Macros also allow for naming gcodes with easier to remember names. Then. Then reduce the distance, and stop just before the filament disappears into the hot end. After I have executed the M302 S1 command, the extruder moves a few steps in one direction and then stops.